{"id":544,"date":"2025-04-09T08:46:25","date_gmt":"2025-04-09T06:46:25","guid":{"rendered":"https:\/\/www.rewitec.com\/?p=544"},"modified":"2025-09-08T09:15:52","modified_gmt":"2025-09-08T07:15:52","slug":"rewitec-on-the-2-disc-test-bench","status":"publish","type":"post","link":"https:\/\/www.rewitec.com\/en\/rewitec-on-the-2-disc-test-bench\/","title":{"rendered":"REWITEC\u00ae on the 2-disc test bench"},"content":{"rendered":"<p>The Competence Centre for Tribology at the University of Mannheim used the 2-disc test bench to investigate the friction and wear behaviour of materials and coatings as well as the lubricant properties under rolling and rolling load. Thanks to the modern test procedure, the data (e.g. frictional torque) can be continuously recorded digitally. It is also possible to determine mass wear by weighing.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Scientific investigation with Castrol X320<\/h2>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.rewitec.com\/files\/images\/content\/wissenschaftliche-tests\/2-scheiben-pruefstand.jpg\" alt=\"\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The red graph is without REWITEC<sup>\u00ae<\/sup><\/li>\n\n\n\n<li>The blue graph is labelled with REWITEC<sup>\u00ae<\/sup>\u00a0added after approx. 20 hours<\/li>\n\n\n\n<li>The green graph is labelled with REWITEC<sup>\u00ae<\/sup>\u00a0right from the start<\/li>\n\n\n\n<li><strong>Up to 46% less surface roughness<\/strong><\/li>\n\n\n\n<li><strong>Up to 22% less frictional force<\/strong><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Scientific investigation with AGIP SX320<\/h2>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.rewitec.com\/files\/images\/content\/wissenschaftliche-tests\/vorher-nachher-vergleich.jpg\" alt=\"\"\/><\/figure>\n\n\n\n<p>REWITEC coating in a before\/after comparison: SEM images after the long-term test<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">The investigations confirm this:<\/h3>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.rewitec.com\/files\/images\/content\/grafiken\/rewitec_20-prozent-weniger-temperatur.png\" alt=\"20% less temperature\"\/><\/figure>\n\n\n\n<p>20 % less temperature<br>in gearboxes and bearings*<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.rewitec.com\/files\/images\/content\/grafiken\/rewitec_33-prozent-weniger-reibung.png\" alt=\"33 % less friction in gearboxes and bearings\"\/><\/figure>\n\n\n\n<p>33 % less friction<br>in gearboxes and bearings*<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.rewitec.com\/files\/images\/content\/grafiken\/rewitec_50-prozent-weniger-rauhigkeit.png\" alt=\"50 % less roughness on metal surfaces\"\/><\/figure>\n\n\n\n<p>50 % less roughness<br>on metal surfaces*<\/p>\n\n\n\n<p>* Data according to rolling wear tests on the 2disc test bench of the Competence Centre for Tribology at Mannheim University of Applied Sciences 09\/2012<\/p>","protected":false},"excerpt":{"rendered":"<p>The Competence Centre for Tribology at the University of Mannheim used the 2-disc test bench to investigate the friction and wear behaviour of materials and coatings as well as the lubricant properties under rolling and rolling load. Thanks to the modern test procedure, the data (e.g. frictional torque) can be continuously recorded digitally. It is also possible to determine mass wear by weighing. Scientific investigation with Castrol X320 [...]<\/p>","protected":false},"author":1,"featured_media":547,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","inline_featured_image":false,"footnotes":""},"categories":[20],"tags":[],"class_list":["post-544","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-forschung"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.rewitec.com\/en\/wp-json\/wp\/v2\/posts\/544","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rewitec.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.rewitec.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.rewitec.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rewitec.com\/en\/wp-json\/wp\/v2\/comments?post=544"}],"version-history":[{"count":1,"href":"https:\/\/www.rewitec.com\/en\/wp-json\/wp\/v2\/posts\/544\/revisions"}],"predecessor-version":[{"id":548,"href":"https:\/\/www.rewitec.com\/en\/wp-json\/wp\/v2\/posts\/544\/revisions\/548"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rewitec.com\/en\/wp-json\/wp\/v2\/media\/547"}],"wp:attachment":[{"href":"https:\/\/www.rewitec.com\/en\/wp-json\/wp\/v2\/media?parent=544"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.rewitec.com\/en\/wp-json\/wp\/v2\/categories?post=544"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rewitec.com\/en\/wp-json\/wp\/v2\/tags?post=544"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}